Operation manual intended for professionalsand end users.To be saved for future consultationDocument n° 1534-1 ~ 13/06/2012Fujitsu General (Euro) GmbH
3.5 Setting the timegure 7 - 04 8 12 16 20 24AUTO204 8 12 16 20 24AUTO304 8 12 16 20 24AUTO404 8 12 16 20 24AUTO1504 8 12 16 20 24AUTO60 4 8 12 16
3.6 Structure of the "End user" control menu1232050050150250350450550651551664164264364871071271467117141841084128413870087018702...8900
3.7 Parametering the setting3.7.1 GeneralOnly the parameters accessible to levels:End userAre described in this document.The parameters accessible a
Line Function Setting range or displaySetting incrementBasic settingTime program heating, circuit 1500 Pre-selection (Day / Week) Mon-Sun, Mon-Fri,
Line Function Setting range or displaySetting incrementBasic settingTime program 5 / CoolingIf the installation is tted with the cooling kit (Only
Line Function Setting range or displaySetting incrementBasic settingDomestic hot waterIf the installation is tted with the DHW kit (Only with the D
- Various data (see below). Designation LineFloor drying current setpoint . -Current drying day. -Terminated drying days. -State heat pump. 8006State
3.10 Operation of the DHW systemThe key enables you to switch the DHW (domestic hot water) mode on and off. The selection is shown by a bar,
4 MaintenanceIn order to insure your appliance operates correctly for many years, the maintenance operations described below are required at the
Operation manual "1534 - EN"- 19 -Air to Water Heat Pump
ContentsInstructions to be read before using the equipment . . . . . . . . . . . . . . 3Safety instructions . . . . . . . . . .
Date of installation :Contact of your heating technician or your after-sales service. This appliance is marked with this symbol. This means that ele
1 Instructions to be read before using the equipmentPlease comply with the following instructions in order to avoid any risk of injury o
1.2 Precautions and warnings regarding your installation.1.2.1 The outdoor unitThe outdoor unit contains the equipment for capturing energy from t
2 Overall view of the installationYour heat pump has been congured by your installer. It is composed of the following main elements: - The outdoor u
3 Operation of the installation3.1 User interface, Remote control (option) and Room thermostat (option)gure 2 - °CAutoAutoESCOK0 4 8
Ref. Functions - Denitions1 Selecting of the DHW operating mode (Domestic hot water).OnOff - If the installation is tted with a DHW tank. - On:
gure 3 - 3.2 Description of the displaySymbols Denitions - Heating mode active with reference to the heating circuit. - Heating in comfort mode. -
3.3 Appliance start up• The installation and 1st start up of the appliance must be done by a qualied installer. That person will also give y